Dongguan Sun Young Resource Limited-Dongguan Sheng Yang Industrial Co., LTD

Home > Product > Off Grid Inverter > Solar Controller
Filter Products

SY-PWM-80A

80A Solar Controller Charge Regulator 12V 24V Auto Switch Solar Panel Battery Charge Controller Free Shipping
  1. Detailed information
  2. Detail display
  3. Warranty

LCD Display PWM Solar controller 12V/24V 80A for solar system

 
3 Control modes to choose:
 
1.Charge Only
2.Light Control
3.Light and 15hours timer control(Settable)
 
Package Included:
1. 1X solar controller
2. 1X Users` Manual
3. 1X Temp. Sensor
 
80A Solar Panel Charge Controller 12V/24V + LCD display Compatible with MAX 1440W Solar Panel 12V/24V Auto Switch;Timer Intigrated (Lighting function)
 
Features:
Solar LCD series a kind of intelligent,multipurpose solar charge and discharge controller
1, LCD screen display
2, Easy operation interface
3, PWM charging mode
4, Parameter user can reset,
5, A key to open and close the load,
6, A key to restore the factory settings,
7, Battery reverse discharge protection,
8, Battery reverse polarity protection
9, Battery under voltage protection,
10, Overload, short-circuit protection,
11, Automatic temperature compensation function,
12, USB 5V charging (for 500mA) for mobile phone.
 
Installation
1. Ready tools and cables. Encourage you to matching the right cables. Ensure that the current density<4mm2 that is conductive to reducing the line voltage drop. Recommended: 60A with 20mm2 cable. Check weather the installation sitescompliance with the relevant safety requirements. Please avoid the damp, dusty, there is a place flammable, explosive and corrosive gases use the controller to install.
2. Install the controller into a fixed vertical plane. See section 5 of the pore size and pore spacing. In order to ensure a good thermal control conditions, please set aside each 10cm below the controller space.
3. As shown on the right, connect the (1) Load, (2) Battery and (3) Solar Panel to the controller according to the order of (1) (2) (3). Pay attention to the load, battery, solar panel and controller of same polarity.
4. Put into the external temperature sensor on the left of the controller (probe port). The temperature sensor should be similar space with battery. (Otherwise, the controller will control the parameters of all wrong temperature compensation.)
5.If you have remote monitoring and control function, please insert one end of the included communication wire on the right of the controller (communication port), the other end to connect to The host computer.
Demolition: To prevent accidents, please order the demolition of solar panels, battery and load disconnect with controller.
Note:Battery polarity will not damage the controller, but you will have a load equipment security risk